PolySoft Monitor |
|
No. |
Type |
Description |
| 1 |
CH |
Honeycomb die corrected. This die type does not have a
heating zone. |
| 2 |
NF |
New die type PTW die introduced. This die can be
selected, when PTW is used just with die block. This die does not have a
heating zone, but provide a singe sensor port. |
| 3 |
BF |
Torque calculated from motor current (no sensor
connected) is now displayed as a sensor display (in previous version is
was displayed as a controller, but torque control did not work of
course). |
| 4 |
CH |
In Device Setup dialog page Dies has been enhanced. Now
2 additional heating zones (called Bypass and additional zone)
can be used. Now all possible 4 heating zones can be used when
MeltPump OS is connected. |
| 5 |
BF |
In the past occasional reviving of not died sensors
caused the Monitor OS software to switch back to Monitor view. BaseCan
is now more stable in recognition of sensor (specially TM sensor)
heartbeats. |
| 6 |
NF |
New device introduced Rheomex 19/20 OS to
recognize Rheomex 202 units mounted on a Docking OS
correctly. |
| 7 |
BF |
Now torque values derived from the motor current (no
torque sensor present) are available to be displayed in the diagram (Workaround
is obsolete). |
| 8 |
BF |
PolySoft OS did not accept 70 as rpm setpoint
for MeltPump OS although no error message occurred. 69.9 was
accepted. Now full setpoint range 0.1 ... 70.0 rpm ca be set. |
| 9 |
BF |
The temperature setting dialog did not react as assumed
in special circumstances. |
| 10 |
NF |
The current Device setup can be printed, copied to
the Clipboard and saved as a bitmap file from a new Context menu in the
Monitor view. |
|
PolySoft OS application (general) |
|
No. |
Type |
Description |
| 1 |
NF |
New Software-Keys introduced to install an evaluation
only software for Mixer and Capillary application |
| 2 |
BF |
Even if import of HB2 data files was possible in
previous versions, the file filter was missing in the dialog to open the
imported file. Filter *.HB2 files now added to the import filter. |
| 3 |
CH |
Graphic transfer from main application to printout (and
preview) tool List & Label changed. Previous versions used WMF (Windows
Meta File) format. Changed to more uo to date EMF (Enhanced Meta File)
format. This change should avoid occasional errors on Japanese Windows
PCs. |
| 4 |
CH |
Used List & Label version changed from 10.0 to 12.0. In
the setup some DLLs are replaced. |
| 5 |
NF |
In value read dialog new entry Gradient added.
It contains the linear slope of the selected range. the units of Y- and
Y-axis are used as selected. If i.e. torque is displayed versus time and
time unit is min. the gradient unit is Nm/min. |
| 6 |
CH |
Operation mode to define a range to read values, has
been changed. |
| 7 |
EX |
When the mouse pointer hovers over an element's icon in
the Project view, a tooltip window will pop up. This tooltip displays
the contents of the currently marked measurement entry.
 |
| 8 |
NF |
The current table layout in the Project view is
saved with the project. The order of the columns and column width can be
changed by Drag & Drop. |
|
Mixer Test software |
|
No. |
Type |
Description |
| 1 |
NF |
In Multi Segment Mixer measurement a temperature and
rotor speed gradient can be defined for each step (Except first step).
Temperature and rotor speed will be changed using the given gradient
when new setpoint is controlled. |
| 2 |
NF |
In a small dialog heating (or cooling) times can be
calculated when gradients are defined. |
| 3 |
BF |
Even if import of HB2 data files was possible in
previous versions, the file filter was missing in the dialog to open the
imported file. Filter
*.HB2
files now added to the import filter. |
| 4 |
BF |
Defining new evaluation routines (or modifying existing
ones) changed. In previous versions some parameters for maxima are
not used correctly. |
| 5 |
CH |
Some dialog texts have been introduced to translation
table. By this i.e. Allgemein in Multi Step dialog ins now
General in English. |
| 6 |
BF |
In some rare occasions calculated energy started not
with a value of zero. |